CUSTOM STRINGERS
SUGGESTED REINFORCEMENTS
▪ (2X10) OR (2X8) BEAM*
Step nosing
D. Beam: if (2x10) qty 2 if (2x8) qty 3
B. Fixing plate
A.
Thickness: 1 /
4 "
B.
D.
H
H
C. Plywood
• Thickness: 5 / 8 " minimum • Width : wider than or equal to the joist • H : measure from the finished subfloor to the bottom of the beam • Screw and glue to the beam
A. Finishing
Example : wood, gypsum panel...
The use of construction glue such as ‘‘PL PREMIUM’’ is recommended.
▪ I-BEAM*
E. I-beam
Step nosing
A.
B. Fixing plate
Thickness: 1 /
4 "
B.
H
E.
H
D. Strapping • Total thickness, including the I-beam: 3" minimum • Length 36" minimum • Screw and glue to the beam
C. Plywood
• Thickness: 5 / 8 " minimum • Width: wider than or equal to the joist • H: measure from the finished subfloor to the bottom of the beam • Screw and glue to the beam
D.
C.
A. Finishing
Example : wood, gypsum panel...
The use of construction glue such as ‘‘PL PREMIUM’’ is recommended.
Photos and drawings are indicative. The installer is responsible for checking the current regulations, in their area, with their local building inspector.