Awnings | Elevation Charts
Awnings – Single Units
Awnings | Single Units
1'-10 1/2" 1'-8 1/2" 15 1/4" 13 13/16"
2'-2 1/2" 2'-0 1/2" 19 1/4" 17 13/16"
2'-6 1/2" 2'-4 1/2" 23 1/4" 21 13/16"
U.D.
3'-2 1/2" 3'-0 1/2" 31 1/4" 29 13/16"
2'-8 1/2" 2'-6 1/2" 25 1/4" 23 13/16"
4'-2 1/2" 4'-0 1/2" 43 1/4" 41 13/16"
2'-10 1/2" 2'-8 1/2" 27 1/4" 25 13/16"
3'-8 1/2" 3'-6 1/2" 37 1/4" 35 13/16"
R.O.
G.S.
G.S.*
1818
2018
2418
2618
2818
3018
3618
4018
1820
2020
2420
2620
3020
2820
3620
4020
1826
2026
2426
3026
2626
3626
2826
4026
1830
2030
2430
4030
2630
2830
3630
3030
* Glass size for push-out awnings U.D. = Unit Dimension • R.O. = Rough Opening • G.S. = Glass Size
Awnings – Single Picture Units
Awnings | Single Picture Units
1'-10 1/2" 1'-8 1/2" 15 1/4" 13 13/16"
2'-2 1/2" 2'-0 1/2" 19 1/4" 17 13/16"
3'-2 1/2" 3'-0 1/2" 31 1/4" 29 13/16"
2'-6 1/2" 2'-4 1/2" 23 1/4" 21 13/16"
2'-8 1/2" 2'-6 1/2" 25 1/4" 23 13/16"
3'-8 1/2" 3'-6 1/2" 37 1/4" 35 13/16"
4'-2 1/2" 4'-0 1/2" 43 1/4" 41 13/16"
2'-10 1/2" 2'-8 1/2" 27 1/4" 25 13/16"
U.D.
R.O.
G.S.
G.S.*
4040
1840
2040
2440
2640
3640
3040
2840
4050
1850
2050
2450
2650
3650
3050
2850
2460
1860
2060
2660
4060
3060
3660
2860
* Glass size for push-out awnings U.D. = Unit Dimension • R.O. = Rough Opening • G.S. = Glass Size
Dimension Calculations
Elevation charts provide wood unit dimensions for units with the standard 1-15/16" brickmould. Below are the calculations to determine the frame size of units with brickmould. -2" 3-1/2" flat or profiled casing; U.D. to F.S. -5 5/8" -3 9/16" 3-1/2" casing and backband; U.D. to F.S. -7 1/8" -4 5/16" Height 1-15/16" brickmould; U.D. to F.S. -2 1/2" Width
F.S. to Sash O.S.M. Sash O.S.M. to G.S.
-1 15/16" 1 15/16" -2 13/16" 2 13/16"
G.S. to D.L.O.
NOTE: All measurements are nominal. Elevation charts are not to scale. Divided lites are optional. Some installation procedures will require a larger rough opening than noted (i.e. installations utilizing our installation clips), therefore, you may need to increase the rough opening size accordingly. Rough opening gaps may be increased up to a maximum of 1/2" on all sides and still be within good practice guidelines. For rough opening recommendations, see pg. 194. Additional and the most current drawings are available at www.kolbewindows.com .
-1"
-1"
G.S. to Screen O.S.M. U.D. to G.S. (for push-outs)
+1 9/16" +1/2" -8 11/16" -8 3/16"
F.S. = Frame Size • G.S. = Glass Size • O.S.M. = Outside Measurement D.L.O. = Daylight Opening • U.D. = Unit Dimension
Kolbe Windows & Doors 58